OK
|
#
|
ITEM
|
CODE
SEC.
|
|
GENERAL
|
| |
1.
|
Obtain
building and electrical permits.
|
111.1
|
| |
2.
|
At
least one means of egress (exit) from the pool.
|
623.5.5
|
| |
3.
|
Pool
equipped with filtration system.
|
623.6.1
|
| |
4.
|
Barrier
(fence, pool wall, etc.) shall be not less than 48" in height.
|
623.10.1
|
| |
5.
|
Openings
shall not allow passage of a 4" sphere.
|
623.10.2
|
| |
6.
|
No
indentations/protrusions in solid barriers.
|
623.10.3
|
| |
7.
|
Horizontal
rails less than 45" apart on inside barrier; 1-1/4" vert.
spacing
|
623.10.4
|
| |
8.
|
Horizontal
rails spaced 45" or more vertical/picket spacing 4" O.C.
max.
|
623.10.5
|
| |
9.
|
Maximum
diagonal chain link mesh openings 1-1/4".
|
623.10.6
|
| |
10.
|
Maximum
diagonal openings (lattice, chain link w/slats etc.) 1-3/4"
|
623.10.7
|
|
ACCESS
GATES
|
| |
11.
|
Gate
material shall comply w/ #4 through #10 above.
|
623.10
|
| |
12.
|
Gates
shall open outward, away from pool.
|
623.10.8
|
| |
13.
|
Gates
shall be self-closing, self-latching.
|
623.10.8
|
| |
14.
|
Gate
latches less than than 54" above ground shall be inside gate
and gate material shall have openings 1/2" maximum within 18"
of the latch, which shall be not less than 3" below top of
gate.
|
623.10.8
|
|
ALARMS
FOR DOORS DIRECTLY FROM HOUSE
|
| |
15.
|
Alarm
sounds at least 85db when door/screen is opened (manual overdrive)
|
623.10.9a
|
| |
16.
|
Alarm
sounds for minimum of 30 seconds and is distinctive.
|
623.10.9a
|
| |
17.
|
Alarm
automatically resets.
|
623.10.9a
|
| |
18.
|
Alarm
override permitted, either direction, 15 seconds maximum.
|
623.10.9a
|
| |
19.
|
Touch pads
& switches located 54" minimum above floor.
|
623.10.9a
|